Which command can be used to exit to EXEC mode from this current mode? switch(config-if) #
Which two commands allow you to view the state of high availability between the two clustered Fabric Interconnects? (Choose two.)
Which type of optics module is supported by a 12-port 100 GE Cisco Nexus 7700 F3 Series I/O module?
Which two major components does a Cisco Nexus 1000V Series Switch have? (Choose two.)
Which method does FCIP use to enable connectivity of geographically distributed Fibre Channel SANs over IP?
Which method is a TCP/IP-based protocol for establishing and managing connections between IP-based storage devices, hosts, and clients?
When replacing a standalone C-Series server which order will be used to shut down the server via CIMC?
Which type of optics module is supported by a 6-port 40 GE Cisco Nexus 7000 M2 Series I/O module?
Which two devices does Cisco UCS 5100 Blade Server Chassis support? (Choose two.)
Which group of UCS Virtual Interface Cards is exclusively designed for Cisco UCS C-Series Rack Server?
What is the maximum number of supervisor modules that the Cisco MDS 9710 Switch supports?
Refer to the exhibit.
Which item list all available functions that can be perform to the server?
Which two firmware components does the Host Upgrade Utility upgrade? (Choose two.)
Which type of optics module is supported by a Cisco Nexus 7700 F4-Series 30-Port 100-Gigabit Ethernet Module?
To confirm the installation of a B-Series Server, which GUI based management tool will be used?
Which command syntax is correct to reset the admin password when the switch is in the kickstart prompt?
switch(boot) #"
Which ANSI/TIA-942 data center tier provides up to 99.982% uptime availability per year?
Which two types of information does the show module NX-OS command display? (Choose two.)
In the Cisco UCS S3260 Storage Server which two of the below ports are available on a System I/O Controller? (Choose two.)
Refer to the exhibit. Drag and drop the fault icons from the left onto the description on the right.
Which three troubleshooting procedures do you perform when there is no power to a Cisco UCS B250 M2 Blade Server? (Choose three.)
Refer to the exhibit.
Which Cisco MDS chassis supports the 48-Port 16-Gbps Fibre Channel Switching Module?
Which two commands display the version of Cisco NX-OS code that the device is currently running on? (Choose two.)
Refer to the exhibit.
Which two faults can occur if the System Health LED is in a steady amber state? (Choose two.)