Where must a diesel engine driven fire pump's fuel tank be located for areas subject to temperatures below 32°F (0°℃)?
In an existing system, the vertical clearance between a high volume low speed (HVLS) fan and a sprinkler shall be
What is the hose stream allowance and duration for rolled paper storage protected using ESFR sprinklers?
Four sprinklers are in a 460 ft2 (42.7 m2) room of ordinary hazard, Group 1 occupancy. Each sprinkler coverage area
is 120 ft2 (11.1 m2). What is the minimum water required from each flowing sprinkler?
The minimum design criteria for the design of a new sprinkler system in a residential occupancy, with noncombustible concealed spaces, in an NFPA 13 based design is how many residential sprinklers and what density?
What is the maximum distance an underground main can be installed under the building to the riser location without
additional requirements?
A sprinkler system has been installed with 100 sprinklers. What is the minimum number of spare sprinklers to be provided?
When utilizing ordinary temperature CMDA sprinkler protection for a single-row rack storage of an unencapsulated Class I commodity stored 15 ft (4.6 m) high without in-rack sprinklers with 8 ft (2.4 m) aisles, what is the minimum design density required?
What is the required density for a warehouse with 10 ft (3 m) deep multiple-row racks without an in-rack sprinkler
system that contains a nonencapsulated storing Class IlI commodity on wooden pallets and has a storage height of
18 ft (5.4 m) and 8 ft (2.4 m) aisles, and is using standard, ordinary temperature sprinkler heads?
How much pressure is lost due to elevation in water flowing in a pipe from 6 ft (1.8 m) high to 15 ft (4.6 m) high?
What is the equivalent length of a 45° elbow of 6 in (150 mm) Schedule 10 pipe?
A five story building is proposed, with the ground floor being used for retail space and the upper four floors for
apartments. There is no 3-hour rated building separation between the retail and residential spaces. Which standard is
applicable for the design of the fire sprinkler system?
For an Ordinary Hazard with a design area of 1,500 ft2 (140 m2), what is the minimum number of standard pendent sprinklers required?
What is the minimum calculated design area for a light hazard sprinkler system protecting an open office space with a
noncombustible acoustic ceiling tile installed 6 in. (150 mm) below the bottom of solid wood joists?
A warehouse has palletized storage of empty wood crates on wood pallets to a height of 11 ft (3.4 m). What is the
minimum design density?
What ASTM standard covers the manufacture of chlorinated polyvinyl chloride (CPVC) pipe, allowed to be used in fire
sprinkler systems?
Contract specifications call for a water mist fire protection system in the mechanical room. Is this allowed per
NFPA 13?
A sprinkler system employing automatic sprinklers that are attached to a piping system that contains air that might or
might not be under pressure, with a supplemental detection system installed in the same areas as the sprinklers, is
known as a:
A kitchen in a restaurant encompasses an area of just over 700 ft2 (65 m2) with 2-hour fire rated walls. Does this meet the definition of a small room?